fluidyn PANEPR

  

Very powerful 3D CFD modeling tool, for solving and planning the response to the consequences due to accidental  gaseous releases. 

 

fluidyn PANEPR is applied for emergency planning and response services. It  mainly deals with the accidental consequences of gaseous releases from pressurized storage tanks, pipes, pressurized boilers and distillation columns. The gaseous releases may occur due to the rupture or leak in pressurized or non- pressurized tanks, pipes, valves, joints etc. This is one of the most powerful tools, used for solving and planning the responses to accidents that could be caused by the gaseous releases.

fluidyn PANEPR can easily  simulate complex chemical reactions. This model can do the source calculation by computational fluid dynamics for pipeline and storage tank leaks. It can be applied in exact simulation of flow between the buildings and chemical units by curvilinear mesh and second order solver.

Dispersion of dense gases and combustion

   
USER INTERFACE
I-O PARAMETERS
  APPLICATIONS

...back to top

USER INTERFACE

Please Refer fluidyn PANACHE User Interface.

...back to top

INPUT & OUT PARAMETERS

fluidyn PANEPR is tool of fluidyn PANACHE family. It shares the  GUI of fluidyn PANACHE. Input and output parameters, are part of  pre and post processors which in turn are part of GUI. Following input & output parameters are similar for all the tools of this family

 

INPUT PARAMETERS

OUTPUT PARAMETERS

  • Geometry of the domain
  • Terrain data
  • Meteorological data
  • Chemical properties
  • Pollutant source data
  • Boundary conditions
  • Pressure and Total Head at Various locations.
  • Velocity components U, V, W at various locations.
  • Pollutant quantity or concentration level at various locations
  • Density and viscosity variations (due to pollutants) at various locations.
  • Temperature gradients at different locations
  • Time averaged concentration of pollutants

...back to top

APPLICTAIONS

  • Heavy gas dispersion with stratification and heat exchange with ground
  • Multiple sources: Stacks, storage tanks, pipelines, area sources
  • Rainout : Droplet formation, transport and evaporation of aerosol and liquid pools
  • Source calculation by computational fluid dynamics for pipe-line and storage tank leaks
  • Interaction with structures (Reservoir and tanks)
  • Explosion and fire: Flame propagation, smoke formation, radiation. visibility
  • Interaction with structures (reservoirs and silos)
  • Rapid estimation : In case of industrial leakage
  • Accumulation of natural radon gas in valleys and mines
  • Atmospheric chemical reactions or photochemical reactions
  • Exact simulation of flow between building and chemical units by curvilinear mesh and a second order solver.
  • topography and ambient conditions: steep slopes, temperatures

...back to top

dsd
For more information:

...back to top

          For more information contact             Transoft International
           Tel: 33-(0) 1-42 43 16 66
          Fax: 33-(0) 1-42 43 50 33
         Email:  support@fluidyn.com

Transoft International
webmaster@fluidyn.com


Home | UserClub | Download | Papers | Careers | ContactUs | Evaluation studies